Copper Averaging Probe from Enercorp Instruments

Copper, Averaging Probe, Enercorp InstrumentsOur probe is constructed of a bendable copper 1/4 inch O.D. tube. Inside the probe numerous sensors are encapsulated at equal distances along the length of
the sheath. The complete assembly acts as a single temperature sensor and any temperature change is averaged across the sensors. The probe can easily be
bent to fit any size duct.

For lengths up to 12 feet or for most economical applications, we average the readings of four internal sensors. For 24 foot probes and more demanding applications, we use nine sensors spaced along the length of the sheath.

Our molded case with hinged cover is easy to install.

The cover is fastened with one captive screw. Provision is made for a front identification tag. The back is completely smooth so it fits flush against the mounting surface. Circuit board slots inside are designed to accept a 2-wire transmitter if required

Inside the Copper Averaging Probe numerous sensors are encapsulated at equal distances along the length of the sheath. The complete assembly acts as a single temperature sensor and any temperature change is averaged across the sensors. The Copper Averaging Probe can easily be bent to fit any size duct.

The rigidity of the copper tube may make it easier to install in applications where the sensor must be fed through a thick wall. It is somewhat more expensive than our Flex-Cable Averaging Sensor which has the same function.

Technical Data

Platinum RTD's are the most stable temperature sensors between -50 and 400C. Their stability, wide temperature range and almost linear output make them the choice in demanding applications. Our standard RTD’s use 100 or 1000 ohm thin film elements to DIN 43 760 (IEC 751) class B with a tolerance of 0.3 deg C. We also supply class A thin film RTD’s as well as sensors with wire wound elements in class B, class A and 1/5 DIN tolerances.

NTC Thermistors are the most sensitive sensors known for temperature measurement from -50C to +150C.

The temperature coefficient of thermistors can be as high as several percent per degree C. This means that lead resistance from installation of thermistors in remote areas has minimal effect on system accuracy.

Since they are semiconductors they must not be exposed to temperatures near their maximum operating limits or they can drift out of specified tolerance.

Our standard thermistor has a 10K resistance at 25C and a tolerance of +/- 0.2C. On request other calibrations and accuracies are available.

Operating Temperature The construction of these sensors limits their maximum operating temperature to 105C.

Data Sheet

Installation & Operation

 

| Back to Temperature Sensors


ENERCORP INSTRUMENTS LIMITED

About Enercorp

Enercorp Instruments Ltd is a Manufacturer of Temperature, Pressure & Humidity Instrumentation. Used for Industrial, Food Processing, Climate Monitoring & Energy Management Applications.

Sitemap

Enercorp Products

Our products include temperature, pressure, humidity & climate instruments for sensing, controlling, recording and indicating; as well as wind speed & direction systems, RTD elements, smokehouse probes & custom built RTD, thermocouple and thermistor temperature sensors, temperature transmitters/transducers, thermowells, moisture meters, signal conditioners, power supplies, air quality & gas monitors..

Contact Enercorp

  • Toll Free:
    1-800-363-2677
  • Telephone:
    416-231-5335
  • Fax:
    416-231-7662
  • Email and Website:
    sales@enercorp.com www.enercorp.com
  • Head Office:
    25 Shorncliffe Road,
    Toronto, ON
    M9B 3S4 Canada